Set up the FizzWizz for Health Check testing and verify the power supply green light is on — Check 1 of the Health Check sequence.

Set up and power on

Set up the FizzWizz for Health Check testing and confirm the power supply is functional before entering Test Mode. This is Check 1 and the starting point for the entire Health Check sequence.

Pre-test arrangement

Disconnect both hoses and connect CO₂ to the CO₂_In port before powering on.

Step 1: Physical setup

Power OFF

Ensure the FizzWizz power is OFF before disconnecting or reconnecting any hoses.

Disconnect stone hose

Disconnect the stone hose from the unit.

Disconnect arm hose

Disconnect the arm hose from the unit.

Connect CO₂

Connect the CO₂ supply from the regulator to the CO₂_In port.

Set regulator

Set the CO₂ regulator to approximately 30–40 psi.

Connect temperature sensor

Ensure the temperature sensor is connected to the FizzWizz.

Check 1: Power supply

Connect the wall-wart power supply to the FizzWizz and to a live outlet. The green power light on the supply should illuminate.

Power supply green light

The green light confirms the power supply is functional.

CheckDescriptionResult
Check 1Green power light is ON___

If the green light is off

First confirm the outlet is live and the barrel connector is fully seated in the FizzWizz. If the light remains off, replace the plug-in power supply.

Next step

Test Mode

Enter Test Mode to view live sensor readings and trigger solenoids.