OperationMonitoring Your Carbonation

Monitoring Your Carbonation

How to watch a carbonation run from the FizzWizz display, the BrewWizz dashboard, and the mobile app — and what good data looks like.

Monitoring your carbonation

A carbonation run takes hours to days, and most of it happens unattended. The FizzWizz gives you three ways to keep an eye on it: the front panel, the web dashboard, and the mobile app.

On the front panel

The display shows the three values that drive the carbonation calculation:

FieldWhat it tells you
CO₂ reg psiPressure at the CO₂ inlet. If this drops, your CO₂ supply is running low
Brite psiPressure in the arm/head transfer circuit — the tank head space pressure
TemperatureProduct temperature from the WizzTemp probe

During a normal carbonation run, expect Brite psi to climb steadily toward the finish pressure while temperature stays stable. A temperature that drifts shifts the target pressure with it; the FizzWizz recalculates automatically, but a large drift is worth investigating.

For a live, updating view of all three values plus manual solenoid control, use Test Mode.

On the dashboard

The BrewWizz dashboard is the main monitoring tool for day-to-day use. It runs at bw-dash.allendale.biz and shows:

  • Device health — whether each FizzWizz is reporting, and how recently
  • Telemetry charts — pressure and temperature over time
  • Alert rules and alert history — what has fired and when
  • Recent readings — the latest values from each device

Because the dashboard keeps historical data, it is the best place to answer questions like "when did the pressure stop climbing?" or "has the temperature been drifting all week?". See Device Detail & Charts for how to read the charts.

On the mobile app

The BrewWizz mobile app brings device health, alerts, and account settings to your phone, with the same health states and alert history as the dashboard. It is currently in development — the Mobile App section describes planned features.

What to watch for

These are the signals that most often precede a problem. Each one links to the relevant diagnosis.

SignalLikely meaningWhere to go
CO₂ reg psi fallingCO₂ supply running low, or a regulator problemResponding to Alerts
Brite psi not climbingA leak in the arm or stone circuitCarbonation & Brite Pressure
Brite psi climbing unusually fastLeaking Head_Transfer solenoid, or a broken stoneCheck 6 — Leak Testing
Temperature reading implausible or driftingWizzTemp probe or internal loomSlushy WizzTemp Test
Device showing Stale or OfflinePower, network, or a firmware updateDevice Offline or Not Reporting
Carbonation ends up below targetStone fouling, temperature error, or brite starting pressureCarbonation & Brite Pressure

Using the data for quality control

Recorded telemetry can be kept as a quality record for each batch. Because the dashboard stores the full run, you can correlate a finished batch's carbonation result against the pressure and temperature trace it was produced under — useful for repeatability and for investigating a batch that came out off-target.