MonitoringDevice Detail & Charts

Device Detail & Charts

Using the BrewWizz device detail page — telemetry charts, recent readings, device metadata, and per-device alert rules.

Device detail and charts

The device detail page is where you inspect a single FizzWizz in depth. Open it by selecting a device from the device list.

What the page shows

SectionContents
Telemetry chartsPressure and temperature plotted over time, updating automatically as new readings arrive
Recent readingsThe latest values from the unit
Device metadataSerial number, name, firmware version
Health badgeThe device's current reporting state
Alert rulesThresholds for this device — editable if your plan includes alert rules, otherwise read-only

If your plan does not include alert rules, the page still opens but the alert rules section is read-only. See Understanding Your Plan.

Reading the charts

The charts show the same values the front panel displays, but with history — which is what makes them useful.

MetricWhat to look for
CO₂ reg psiShould hold steady at your regulator setting. A steady decline means the CO₂ supply is running low
Brite psiShould climb steadily during carbonation toward the finish pressure, then hold
TemperatureShould be stable. Drift shifts the required finish pressure with it

What a healthy carbonation run looks like

During a normal run:

  1. Temperature holds steady at the setpoint for the product.
  2. CO₂ reg psi stays flat at 30–40 psi.
  3. Brite psi climbs as CO₂ dissolves, then flattens as the tank approaches the finish pressure for the target carbonation.

The FizzWizz recalculates the required finish pressure continuously as conditions change, so the plateau may shift slightly if temperature moves.

What problem patterns look like

PatternLikely causeWhere to go
Brite psi flat, never climbingA leak in the arm or stone circuitCarbonation & Brite Pressure
Brite psi climbing unusually fastLeaking Head_Transfer solenoid, or a broken stoneCheck 6 — Leak Testing
CO₂ reg psi declining steadilyCO₂ supply running lowResponding to Alerts
Temperature drifting or steppingWizzTemp probe, loom, or glycolSlushy WizzTemp Test
Temperature implausibly low or highFaulty probe or internal loomSlushy WizzTemp Test
A gap in the dataDevice went Stale or OfflineDevice Offline or Not Reporting
Pressure sawtooth patternVent or solenoid cycling unexpectedlyBy Symptom

Recent readings

The readings panel gives the latest values without needing to interpret a chart. This is the fastest way to answer "what is it doing right now?" — useful when checking on a device from your phone.

Device metadata

Metadata confirms you are looking at the right unit and helps support:

FieldUse
Serial numberQuote this when ordering parts or contacting support
NameConfirms which tank this unit serves
Firmware versionSupport will ask for this. Some features — such as the Foot Pressure Sensor — need V2 code or newer

Check the firmware version when installing a Foot Pressure Sensor. It requires FizzWizz-BAE running V2 code or newer. If your unit runs earlier code, contact support about updating it.

Alert rules on this page

Each device has its own alert thresholds. If your plan includes alert rules, you can create and edit them here; if not, they are read-only.

See Alerts & Alert Rules for how rules are evaluated, cooldowns, and where alert history appears.

Using charts for quality control

Because the dashboard retains the full run, you can keep telemetry as a batch record:

  • Correlate a finished batch's carbonation result against the pressure and temperature trace it was produced under
  • Investigate an off-target batch by finding where the trace diverged from a good run
  • Confirm a batch stayed on track through a device outage